Failure analysis

Battery

100062| 2025/05/01 |risk model combined |AIAG-VDA AP + ISO 26262 ASIL combined
6
Findings
2
With action
2 QM
1 AP_M
Event Corrective action Risk
Capacity fade
  Electrolyte degradation
Internal short circuits
Over-dischange AP_M S7 · O100%
AP_L
  Thermal runaway / fire (over discharge) QM SS1 · O100%
Thermal runaway / fire QM SS1 · O0.1%
QM

Risk levels in this report

QM — Quality Managed AP_M — AP: Medium

Action status

Done Resolved — closed on the type, for every instance Not applicable Pending Missing