Failure analysis
Battery
100062
|
2025/05/01
|
risk model
combined
|
AIAG-VDA AP + ISO 26262 ASIL combined
6
Findings
2
With action
2
QM
1
AP_M
Event
Corrective action
Risk
Capacity fade
Electrolyte degradation
Internal short circuits
Over-dischange
AP_M
S7 · O100%
Implement a warning method
AP_L
Thermal runaway / fire (over discharge)
QM
SS1 · O100%
Thermal runaway / fire
QM
SS1 · O0.1%
Add a thermal protection
QM
Risk levels in this report
QM
— Quality Managed
AP_M
— AP: Medium
Action status
Done
Resolved — closed on the type, for every instance
Not applicable
Pending
Missing